HEART Embedded Systems logoHEART

HEART storage.wearing-out H-04004

Storage wearing out. Storage hardware is near the end of its life.

CodeHEART storage.wearing-out; inside a message "code": "storage.wearing-out"
H-numberH-04004: area 04, code 004
Areastorage: Disk, memory cards, databases
Typical severitywarning. A product may set another for its own case.
Applies toProducts with flash cards, eMMC, SSDs or disks

Likely causes

How to fix or prevent it

  1. Back up the data now.
  2. Plan to replace the card or disk soon.
  3. Write less: lower log levels, keep logs in memory, use storage made for endurance.

What the HEART does by itself

It raises a warning from the storage's own health figures (such as SMART or flash wear), and tells a person well before the store fails. It resolves only when the store is replaced.

When to call service

If the storage is built in and cannot be replaced by the owner.


Inside a message a code is written bare, "code": "storage.full". In logs, tickets, documents and searches it is written HEART storage.full. Things that simply happen, such as system.started, are event types, not faults. The codes are defined in Part 3, Section 5.4, and their H-numbers in Section 5.7. All of it, as data: fault-codes.json.

All fault codes, by area · All fault codes, by H-number · Problem types (API errors)